Anyone here worked on the isolated version of the Cuk circuit?

I'm having to deal with a nasty resonance between the d-s capacitance on my n-FET and the magnetizing inductance of the isolation transformer. Shunt damping helps, but still leaves quite a peak. Is this a commonly observed problem or am I just completely missing something. Any suggestions would be very greatly appreciated!

Thanks,
- Udai

PS - Some extra info:
Energy storage/transformer coupling caps = 30uF, Input/Output inductors = 30uF, n-FET = IR L2203N (Cds approx = 1nF), Operating frequency = 150kHz, Xfrmr n=1 and Magnetizing L = 20uH.

Posted by Udai (medicaldeviceguru@yahoo.com) on 13/11/2003, at 15:17 GMT

Re: Isolated Cuk

Never mind - Poor xfmr coupling... Silly goofup.
Regards.

Posted by Anonymous (medicaldeviceguru@yahoo.com) on 13/11/2003, at 19:36 GMT